XY-T01 Digital Thermometer Heating Refrigeration Temperature Control Module

Price:

4.20


5W CREE XTE S3 High Power LED 8-20mm PCB Emitter Warm Neutral White Blue
5W CREE XTE S3 High Power LED 8-20mm PCB Emitter Warm Neutral White Blue
1.06
1.06
30W 40W 50W Driverless LED Light COB Chip Spotlight Size 110x58mm Emitting 60x30mm
30W 40W 50W Driverless LED Light COB Chip Spotlight Size 110x58mm Emitting 60x30mm
5.12
5.12

XY-T01 Digital Thermometer Heating Refrigeration Temperature Control Module

https://www.satistronics.com/web/image/product.template/6533/image_1920?unique=8074831
(0 review)

3.85 3.85 USD 3.85

¥ 28.00

Not Available For Sale


    This combination does not exist.


    Categories :
    Thermometer
    SKU :
    1941272
    Share :
    100% original guarantee
    Return within 30days
    Free delivery on all orders

    Function:

    Set Temperature ---- SetT;

    Backlash Temperature-----BackT;

    1. Heating Mode \'H\':

    • When Temperature ≤ SetT - BackT ;Relay conduction, heating equipment begin to work;

    • When Temperature ≥ SetT, Relay disconnect, heating equipment stop work;

    2. Refrigeration mode \'C\':

    • When Temperature ≥ SetT + BackT ;Relay conduction, refrigeration equipment begin to work;

    • When Temperature ≤ SetT ;Relay conduction, refrigeration equipment stop work;

    3. High Temperature Alarm \'ALA\':

    • When Temperature ≥ Alarm Temperature, The system opens the sound and light alarm, and disconnects the relay, any key stops the sound light;

    4. Delay Start 'OPH\':

    • When a normal heating or refrigeration work is done, the system starts to time T, and only after the T≥OPH, the system can carry out the next round of heating or refrigeration work;

    5. Temperature Correction Function OFE(-10.0 ~ 10.0°):

    •    The system will work for a long time and may have deviations that can be corrected by this function, Temperature = Measured + Calibration;

    6. Parameter Remote Read/Set:

    •    The parameters such as setting temperature, backlash temperature and temperature correction can be set through UART.   

    7. Real-time Temperature Report:

    •    If the temperature reporting function is turned on, the product is transmitted to the terminal by the UART at 1s intervals, which facilitates data collection;

    8. Relay enable (default enable):

    • If the relay is disable, the relay remains disconnected;

    9. Restore factory Settings:

    • At the same time press the STOP, set key more than 3S, restore factory settings;